As the UK’s climate becomes increasingly warmer, the risk of Legionella bacteria thriving in water systems also rises. We are committed to helping property managers, facility operators, and business owners understand and manage these growing risks. Legionella, a bacterium that can cause the severe respiratory illness known as Legionnaires’ disease, thrives in warm water conditions. Given the UK’s changing weather patterns, it’s more important than ever to take proactive measures to safeguard water systems.
Contact Us
The Connection Between Warm Weather and Legionella
Legionella bacteria flourish in water temperatures between 20°C and 45°C, making warm weather a prime environment for its growth. In the UK, cases of Legionnaires’ disease often spike between July and September, the hottest months of the year. As climate change leads to more frequent and prolonged periods of warm weather, the risk of Legionella outbreaks may increase if water systems are not properly managed.
What is Legionella?
Legionella is a naturally occurring bacterium found in freshwater environments like lakes and streams. While generally harmless in nature, Legionella becomes dangerous when it finds its way into man-made water systems such as plumbing networks, cooling towers, hot tubs, and fountains. In these environments, it can proliferate and spread through water droplets in the air, potentially causing Legionnaires’ disease—a severe form of pneumonia that can be fatal, especially in vulnerable individuals.
Key Legionella Risks During Warm Weather in the UK
As temperatures rise in the UK, several factors increase the risk of Legionella growth in water systems:
Warm weather can raise water temperatures in storage tanks, pipes, and other systems, creating ideal conditions for Legionella to grow. This is particularly concerning in large buildings with complex plumbing systems, where temperature fluctuations may go unnoticed.
Warm weather encourages the formation of biofilms—thin layers of organic material that can develop on the inside of water pipes and other surfaces. Biofilms protect Legionella from disinfectants, making it harder to eradicate the bacteria once they have established themselves.
UK summers often bring increased humidity, which can exacerbate the spread of Legionella through water droplets dispersed in the air. This is particularly problematic around cooling towers, evaporative condensers, and air conditioning units that may release contaminated aerosols.
During the summer, some UK buildings such as schools and offices may close or reduce their operations, leading to water stagnation in their systems. Stagnant water creates the perfect environment for Legionella to grow, particularly if the water temperature remains in the bacteria’s optimal range.
Mitigating Legionella Risks During Warm Weather
To reduce the risks posed by Legionella during warm weather, it is crucial for property managers and facility operators to adopt a proactive, comprehensive Legionella management strategy. Proper control measures can help prevent outbreaks, protect public health, and ensure compliance with UK regulations.
Controlling water temperature is the first line of defence against Legionella growth. The bacteria thrive in temperatures between 20°C and 45°C, so maintaining water systems outside of this range is essential.
Keep hot water storage tanks at or above 60°C.
Ensure cold water systems are kept below 20°C.
Regularly monitor and record water temperatures at outlets, storage tanks, and key points in the system.
Insulate pipes to prevent temperature fluctuations that could encourage bacterial growth.
Stagnant water is one of the main risk factors for Legionella proliferation. Implementing a regular flushing programme helps keep water moving and prevents the bacteria from multiplying.
Flush all outlets at regular intervals, paying special attention to those that are infrequently used.
Increase the flushing frequency in areas with low occupancy, especially during summer closures or periods of reduced use.
Document all flushing activities as part of a comprehensive risk management plan to ensure compliance with health and safety regulations.
Monitoring water quality is essential to catching potential issues early and preventing Legionella from establishing itself in your systems.
Develop a robust water monitoring programme that includes monthly temperature checks, pH monitoring, and chlorine level measurements.
Carry out regular water sampling for Legionella bacteria, particularly during warmer months or in high-risk systems.
Keep detailed records of all monitoring activities and any corrective actions taken.
Legionella risk assessments are required by UK law to ensure that water systems are properly managed and maintained.
Conduct a thorough Legionella risk assessment annually, or whenever there are significant changes to the water system.
Pay particular attention to summer months when risks are elevated due to increased temperatures.
Make sure all parts of the water system are covered in the risk assessment, including often overlooked areas such as outdoor water features and irrigation systems.
Additional Legionella Control Measures
While temperature control, flushing, and monitoring form the foundation of a solid Legionella management plan, other systems in your facility may also pose risks that require specific attention:
Cooling towers are a known source of Legionella, as they can disperse contaminated water droplets into the air.
Adhere strictly to UK guidelines regarding the operation and maintenance of cooling towers.
Implement a routine cleaning and disinfection schedule to prevent the buildup of biofilms and other contaminants.
Regularly test the water in your cooling tower and adjust treatment protocols as necessary.
Outdoor water features such as fountains, sprinklers, and irrigation systems are often overlooked in Legionella risk management, but they can harbour bacteria if not properly maintained.
Include these systems in your regular risk assessments and maintenance programmes.
Consider draining or treating these systems during prolonged periods of warm weather when Legionella risks are higher.
The Impact of Climate Change on Legionella Risks
As the UK’s climate continues to warm, Legionella risks are likely to increase. Prolonged warm seasons, more frequent heatwaves, and extreme weather events such as heavy rainfall and flooding all contribute to conditions that favour Legionella growth. Property managers need to consider the long-term implications of climate change on their Legionella management strategies.
Longer periods of warm weather extend the risk period for Legionella growth beyond the traditional summer months, requiring more vigilant monitoring and management throughout the year.
Increased rainfall and flooding, often linked to climate change, can introduce contaminants into water systems and increase humidity levels, both of which encourage Legionella growth. After flooding or severe weather, it’s essential to inspect water systems and test for Legionella contamination.
As climate change affects how buildings are used, with potential shifts in occupancy patterns or cooling requirements, new risk scenarios may emerge. It is important to remain flexible and adapt Legionella management strategies to evolving conditions.
UK Regulations and Legionella Management
In the UK, Legionella management is governed by several key regulations, all designed to protect public health and ensure water systems are maintained to prevent contamination:
- The Health and Safety at Work etc. Act 1974
- The Control of Substances Hazardous to Health Regulations 2002 (COSHH)
- The Management of Health and Safety at Work Regulations 1999
- HSE’s Approved Code of Practice L8 (ACOP L8)
These regulations place specific responsibilities on property owners and managers to assess, manage, and control the risk of Legionella in water systems. Regular testing, monitoring, and reporting are essential for compliance and risk reduction.
Legionella Testing and Monitoring in the UK
Routine testing and monitoring are critical to managing Legionella risks, especially during warmer months. Key activities include:
- Regular sampling and analysis of water for Legionella bacteria.
- Monitoring the temperature of both hot and cold water systems to ensure they are outside the danger zone for Legionella growth.
- Evaluating the effectiveness of your water treatment programme and adjusting disinfectant levels as needed.
- The frequency of testing may need to be increased during the summer or in high-risk environments, such as healthcare facilities or large commercial buildings.
Stay Ahead of Legionella Risks
As the UK continues to experience warmer weather, managing Legionella risks is more important than ever. We offer expert guidance and services to help you stay compliant and protect the health of your building occupants. From risk assessments to comprehensive monitoring and testing, we have the solutions you need to keep your water systems safe.